TNV2T502 Is Huawei OptiX OSN 9800 2 Port 40GE/50GE/100GE/200GE Tributary Service Processing Board
Huawei OptiX OSN 9800 2 Port 40GE/50GE/100GE/200GE Tributary Service Processing Board TNV2T502 Overview
TNV2T502 Is Huawei OptiX OSN 9800 2 Port 40GE/50GE/100GE/200GE Tributary Service Processing Board
Apply to Huawei 9800 M24,9800 U32 Enhanced,9800 U32 Standard,9800 U64 Enhanced,9800 U64 Standard Transmission Platforms
TNV2T502: 2*40GE/50GE/100GE/200GE Tributary Service Processing Board
As an OTN tributary board, the T502 board can support a mix of ODU0, ODU1, ODU2(e) and ODUflex signals.
The board TNV2T502 Have Four indicators are present on the front panel:
Board hardware status indicator (STAT) - triple-colored (red, green, yellow)
Service active status indicator (ACT) - dual-colored (red, green)
Board software status indicator (PROG) - dual-colored (red, green)
Service alarm indicator (SRV) - triple-colored (red, green, yellow)
Huawei OSN 9800 Series Optical Transmission Platform's board category as below:
OTN Tributary Board
OTN Line Board
Universal Line Board
General Service Processing Board
Packet Service Processing Board
EoO Board
SDH Board
EoS Board
Turbo WDM Board
Submarine Board
Clock Board
Cross-Connect Board
System Control and Communication Board
Functions and Features of the TNV2T502 Board (OTN Tributary)
Function and Feature |
Description |
Backplane capacity |
The maximum capacity is 400 Gbit/s. |
Client-side service type |
NOTE: The client-side port type is QSFP4*28G by default, and the access service type can be set to 100GE or OTU4. If other client-side services need to be transmitted or received, the port type must be changed. For example, if 50GE services need to be transmitted or received, you need to change the port type to Client Side Grey Optical Port. If 200GE services need to be transmitted or received, you need to change the port type to Lane4*56G. For a T502 board, two physical ports cannot be bound to a FlexE group. |
Service mapping mode |
|
FEC coding |
|
OTN overhead |
NOTE: Supports overhead processing defined by ITU-T G.709. The service mapping process complies with ITU-T G.709 and G.Sup43. |
LPT |
Not supported |
Client 1+1 protection |
Supported NOTE:
|
ODUk SNCP |
Supported NOTE:
|
Tributary SNCP |
Supported |
Electrical-layer ASON |
Supported |
L1 service encryption |
Supported NOTE:
|
ALS |
Supported when client services are non-OTN services. |
LLDP |
Supported when the client-side service type is ethernet service. NOTE: LLDP is not supported in the case of FlexE services. |
Physical clock |
When the client-side service type is 100GE/50GE the board supports physical clock.
When 200GE (MAC Transparent Mapping) services are received on the client side, synchronous Ethernet processing is supported. When 40GE (TTT+GMP) services are received on the client side, synchronous Ethernet transparent transmission is supported. Supports this function only when the board works with the U2CTU/U4CTU/U5CTU/CXP board and receives FlexE Unaware (100G) and FlexE Aware (200G) services on the client side. |
IEEE 1588v2 |
|
ITU-T G.8275.1 |
|
ITU-T G.8273.2 |
Supported NOTE:
|
High-precision clock synchronization |
Supported NOTE:
|
Outband DCN |
Supportes when the client-side service type is OTU4. |
Test frame |
When the client-side service type is 200GE/100GE/50GE/40GE, the board supports test frame. |
PRBS |
Supported NOTE: The PRBS function in the optical port direction is supported only when the client-side service type is OTU4. |
Latency measurement |
|
Channel loopback |
Not supported |
Port loopback |
NOTE: The board supports ODUk inloop and ODUk outloop only when non-OTN services are received, the port working mode is non-convergence, and bidirectional cross-connections are configured. When the service type is set to None, Inloop, Outloop, and ODUk Outloop are not supported. When non-OTN services are received, the PRBS in the backplane direction can be used only with ODUk loopback. |
Alarm and performance event monitoring |
|