TNS9N401 Is Huawei OptiX OSN 9800 1 Port 100G Hybrid Line Service Processing Board
Huawei OptiX OSN 9800 1 Port 100G Hybrid Line Service Processing Board TNS9N401 Overview
TNS9N401: 1*100G Hybrid Line Service Processing Board (CFP,OTN & OTN+ & SDH)
The TNS9N401 board is a universal line board that supports hybrid transmission of OTN, OSU, and SDH services and converts received service signals into OTU signals.
The TNS9N401 board consists of an ODUk/OSUflex cross-connect module, an OTN processing module, a VC cross-connect module, an SDH processing module, a WDM side optical module, a control and communication module, and a power supply module.
Functions and Features of the TNS9N401 Board
Function and Feature |
Description |
Backplane capacity |
The maximum capacity is 100 Gbit/s. |
WDM specification |
Supports the DWDM specifications. |
Tunable wavelength |
Supports tunable wavelengths of WDM-side optical signals in Super C band (1524 nm to 1573 nm). |
FEC coding |
SDFEC2 |
Line modulation format |
|
Typical channel spacing |
50GHz*n(n=1,2...)(Only the standard center frequency of 50 GHz is supported.) |
OTN overhead protocol |
Supports the OTN frame format and overhead processing defined by ITU-T G.709. |
OTN overhead |
|
OSU |
Supported NOTE: The OSU function requires a license. |
Intra-board 1+1 protection |
Supported NOTE: Supports intra-board 1+1 protection when working with optical protection boards. |
ODUk SNCP |
Supported |
OSUflex SNCP |
Supported NOTE:
|
Tributary SNCP |
Supported |
Electrical-layer ASON |
Supported |
Optical-layer ASON |
Supported NOTE: Only ASON without optical parameters is supported in high SOP mode. |
Digital optical label |
When LS Ability is enabled, the board supports loading low-frequency pilot-tone modulation signals and overheads during wavelength conversion, and can work the optical-layer board that supports the digital optical label function to detect optical power and overheads and report optical performance data. |
Physical clock |
Supported NOTE: When the ODU cross-connect granularity of an OTN line port is set to the maximum granularity supported by the port, physical clock synchronization is not supported. The physical clock can be used only after lower-order ODU cross-connections are configured. |
IEEE 1588v2 |
Not supported |
ITU-T G.8275.1 |
Not supported |
ITU-T G.8273.2 |
Not supported |
Outband DCN |
Supports communication over ESCs. |
Test frame |
Not supported |
PRBS |
Supports the PRBS function on the WDM side. |
Latency measurement |
Supports latency measurement in the WDM-side optical port direction (upstream direction).
NOTE: In the OSU application scenario, unidirectional delay measurement is not supported, and only bidirectional delay measurement is supported. |
Channel loopback |
|
Port loopback |
Supports WDM Side Loopback |