Free cookie consent management tool by TermsFeed
banner
Huawei OSN 9800 OTN 100G Line Board TNU6N404
Huawei OSN 9800 OTN 100G Line Board TNU6N404
Huawei OSN 9800 OTN 100G Line Board TNU6N404
Huawei OSN 9800 OTN 100G Line Board TNU6N404
< >

Huawei OSN 9800 OTN 100G Line Board TNU6N404

TNU6N404 Is Huawei OSN 9800 OTN 100G Line Board

DETAILS

  • Brand Name : Huawei
  • Place of Origin : China
  • Certification : FCC
  • Condition : New Factory Sealed
  • Minimum Order Quantity : 1/Unit
  • Delivery Time : 7 days
  • Model Number : TNU6N404
  • Description : 4 x 100 Gbit/s Line Service Processing Board
 

Huawei OSN 9800 100G Line Board TNU6N404 Overview

N404: 4 x 100 Gbit/s Line Service Processing Board

 

The available functional versions of the N404 board are: TNU4 and TNU5.

 

 

As an OTN line board, the N404 board converts 320 ODU0, 160 ODU1, 40 ODU2, 40 ODU2e, 8 ODU3, 4 ODU4, or 320 ODUflex signals into 4 OTU4 signals carried over 4 ITU-T G.694.1 compliant DWDM wavelength, and vice versa. Each port on the board supports a mix of ODU0, ODU1, ODU2/ODU2e, ODU3, and ODUflex signals. When using colored light modules, the TNU5N404 board can be used in coherent systems.

 

The THU5N404 board supports electrical cross-connections, OTN interfaces, and ESC communication.

 

The N404 board consists of a WDM-side optical module, signal processing module, control and communication module, and power supply module.

 

Only the TNU5N404 board with the colored light optical modules supports the regeneration.

 

The N404 board electrically regenerates four OTU4 optical signals carried over four ITU-T G.694.1 compliant DWDM wavelengths.

The optical receiver on the WDM-side optical module receives four OTU4 optical signals through the IN1-IN4 optical interfaces and converts them into four OTU4 electrical signals.

The OTN processing module performs FEC decoding, overhead processing, and FEC encoding, which is the process of reshaping, regenerating, and retiming the four OTU4 electrical signals and digitally wrapping them into OTN frames.

The OTN-framed OTU4 electrical signals are sent to the optical transmitter on the WDM-side optical module. After performing E/O conversion, the transmitter produces and sends four OTU4 optical signals carried over four ITU-T G.694.1 compliant DWDM wavelengths out the OUT1-OUT4 optical interfaces.

 

There are indicators and interfaces on the front panel of the N404 board.

 

The N404 board requires one slot in a U64/U32/U16 subrack. The N404 board requires two slots in an M24 subrack.

 

In addition to logical ports on the N404 board, this topic describes how the physical ports on the board are displayed on the NMS.

 

Dimensions of the front panel (H x W x D): 477.3 mm (18.8 in.) x 30.5 mm (1.2 in.) x 220.0 mm (8.7 in.)

Weight:

TNU4N404: 4.52 kg (9.96 lb.)

TNU5N404: 4.53 kg (9.98 lb.)

Function and Feature

 

Function and Feature

Description

Basic function

Supports the following service conversions:

  1.  

320 x ODU0/160 x ODU1/40 x ODU2/40 x ODU2e/8 x ODU3/4 x ODU4/320 x ODUflex<->4 x OTU4

  1.  

Each port on the board supports a mix of ODU0, ODU1, ODU2, ODU2e, ODU3 and ODUflex signals.

Cross-connect capabilities

Supports backplane cross-connections of 320 ODU0, 160 ODU1, 40 ODU2, 40 ODU2e, 8 ODU3, 4 ODU4, or 320 ODUflex signals from/to the cross-connect board.

OTN functions

  1. Supports OTU4 on the WDM side.
  2. Supports the OTN frame format and overhead processing defined by ITU-T G.709.
  3. OTU4 layer: supports SM overhead processing.
  4. ODUk (k=0, 1, 2, 2e, 3, 4,flex) layer: supports PM and TCM overhead processing, and non-intrusive monitoring of PM and TCM overheads.

WDM specification

Supports ITU-T G.694.1-compliant DWDM specifications.

Tunable wavelength function

Supports tunable wavelength optical modules that provide for 80 wavelengths tunable in the C band with 50 GHz channel spacing.

TNU5N404 supports tunable wavelength optical modules that provide for 96 wavelengths tunable in the extended C band with 50 GHz channel spacing.

ESC function

Supported

PRBS function

Supports the PRBS function on the WDM side.

FEC coding

  1. When colored light optical modules are used: SDFEC2,HFEC PLUS
  2. When gray light optical modules are used: FEC

NOTE:

Boards that use different FEC modes cannot interconnect with each other.

Alarms and performance events monitoring

  1. Monitors BIP8 bytes (Bursty mode) to help locate line failures.
  2. Monitors parameters such as the bias current, temperature, and optical power of the laser.
  3. Monitors OTN alarms and performance events.

Regeneration board

  1. TNU4N404: Not supported
  2. TNU5N404: The WDM-side signals of a TNU5N404 board can be regenerated using the TNU5N404 board of the same optical modules. Each port supports setting relay mode.

NOTE:

  1.  

When using the gray light optical modules, TNU5N404 does not support the regeneration.

  1.  

Latency measurement

The TNU5N404 board supports latency measurement in the WDM-side optical port direction (upstream direction). When higher-order ODU4 cross-connections are created on the line board, TCM section latency measurement is supported for higher-order ODU4 channels. When lower-order ODUk cross-connections are created on the line board, PM/TCM section latency measurement is supported for higher-order ODU4 channels, and TCM section latency measurement is supported for lower-order ODUk channels.

Test frame

Not supported

IEEE 1588v2

Not supported

Physical clock

  1. TNU5N404: Supported
  2. TNU4N404: Not supported

Electrical-layer ASON

Supported

Optical-layer ASON

Supported

NOTE:

Optical-layer ASON is not supported when a gray light optical module is used.

TNU5N404: In versions earlier than V100R007C00SPC500, ASON is not supported in high SOP mode. In V100R007C00SPC500 and later versions, only ASON without optical parameters is supported in high SOP mode.

Protection scheme

  1. Supports ODUk SNCP.
  2. Supports tributary SNCP protection.
  3. Supports intra-board 1+1 protection (when working with the OLP/DCP/QCP board).

NOTE:

When the cross-connect granularity is ODUflex, the board does not support tributary SNCP protection.

Loopback

WDM Side Loopback

ODU3 Channel Loopback

ODU2 Channel Loopback

ODU1 Channel Loopback

ODU0 Channel Loopback

ODUflex Channel Loopback

Supported

Supported

Supported

Supported

Supported

Supported

 
 

Specifications for Optical Modules

 

Board

Optical Modules

Service type

Optical Module Type

Position

TNU4N404

CFP-100G(4x25G/28G,Dualrate)-1295nm to 1310nm(LR4)-SMF-10km-SP Specifications

OTU4

Pluggable Optical Module

WDM-Side

TNU5N404

CFP-100G(4x25G/28G,Dualrate)-1295nm to 1310nm(LR4)-SMF-10km-SP Specifications

OTU4

Pluggable Optical Module

WDM-Side

TNU5N404

40000 ps/nm-Extended C band-Tunable Wavelength-ePDM-100G QPSK(SDFEC2, ULH+, T5U)-CFP-PIN

OTU4

Pluggable Optical Module

WDM-Side

TNU5N404

CFP-100G-(1529.17nm to 1567.1nm)(DWDM,Tunable, T65)-SMF

OTU4

Pluggable Optical Module

WDM-Side

TNU5N404

CFP-100G-(1529.17nm to 1567.1nm)(DWDM,Tunable, T62)-SMF Specifications

OTU4

Pluggable Optical Module

WDM-Side

TNU5N404

CFP-100G-(1529.17nm to 1567.1nm)(DWDM,Tunable, TxA)-SMF Specifications

NOTE:

  1. Configurable FEC types: SDFEC2, HFEC PLUS.
  2. In a coherent network, the recommended modulation format for the TxA module is QPSK.
  3. In a wDCM network, the modulation format can only be QPSK wDCM for the TxA module.
  4. The QPSK and QPSK wDCM modulation formats cannot interconnect with each other.

OTU4

Pluggable Optical Module

WDM-Side

TNU5N404

100000ps/nm-Extended C band-Tunable Wavelength-ePDM-QPSK(SDFEC2, SLH, T51)-100G CFP

OTU4

Pluggable Optical Module

WDM-Side

TNU5N404

100000ps/nm-Extended C band-Tunable Wavelength-ePDM-QPSK(SDFEC2, wDCM, ULH, T61)-100G CFP

OTU4

Pluggable Optical Module

WDM-Side

TNU5N404

100000ps/nm-Extended C band-Tunable Wavelength-ePDM-QPSK(SDFEC2, SLH+, T50)-100G CFP Specifications

OTU4

Pluggable Optical Module

WDM-Side

TNU5N404

55000ps/nm-Extended C band-Tunable Wavelength-ePDM-QPSK(SDFEC2, ULH, T52)-100G CFP

OTU4

Pluggable Optical Module

WDM-Side

TNU5N404

40000ps/nm-Extended C band-Tunable Wavelength-ePDM-QPSK(SDFEC2, LH, T53)-100G CFP

OTU4

Pluggable Optical Module

WDM-Side

TNU5N404

16000ps/nm-Extended C band-Tunable Wavelength-ePDM-QPSK(SDFEC2 , wDCM, Metro+, T63)-100G CFP

OTU4

Pluggable Optical Module

WDM-Side

TNU5N404

55000ps/nm-Extended C Band-Tunable Wavelength-ePDM-100G QPSK(SDFEC2, ULH, High optical power, T52)-CFP

OTU4

Pluggable Optical Module

WDM-Side

TNU5N404

40000ps/nm-Extended C Band-Tunable Wavelength-ePDM-100G QPSK(SDFEC2, LH, High optical power, T53)-CFP

OTU4

Pluggable Optical Module

WDM-Side

TNU5N404

16000ps/nm-Extended C Band-Tunable Wavelength-ePDM-100G QPSK wDCM(SDFEC2, Metro+, High optical power, T63)-CFP

OTU4

Pluggable Optical Module

WDM-Side

TNU5N404

100000ps/nm-Extended C band-Tunable Wavelength-ePDM-QPSK(SDFEC2, SLH, high optical power, T51)-100G CFP Specifications

OTU4

Pluggable Optical Module

WDM-Side

TNU5N404

100000ps/nm-Extended C band-Tunable Wavelength-ePDM-QPSK(SDFEC2, wDCM, ULH, high optical power, T61)-100G CFP Specifications

OTU4

Pluggable Optical Module

WDM-Side

NOTE:

T5x (SDFEC2, QPSK) can only be used in pure coherent networks. T6x (SDFEC2, QPSK, wDCM) can be used in 10G/40G non-coherent hybrid transmission networks or pure coherent networks. However, in a pure coherent network, the transmission distance of T6x is shorter than that of T5x and therefore is not recommended.

 

 

 
Hunan Moka Information Technology Co., Ltd.
A professional import and export trade company specializing in the agency sales and services of the full range of Cisco products in the United States. Our product range includes Cisco switches, Cisco routers, Cisco firewalls, Cisco wireless APs, Cisco conference terminals, Cisco optical modules, Cisco fiber optic jumpers, Cisco industrial switches, and Cisco software licenses. As an authorized distributor of Cisco in China, we directly purchase hardware and software from Cisco China in the name of projects. As a result, you can obtain the best discounts from Cisco China, typically ranging from 60% to over 90%. Due to Cisco's global sales policy, if you order Cisco licenses, with your consent and permission, we will assist you in installing and activating Cisco licenses within China. Alternatively, you can activate them in your own country, and we will transfer the licenses to you. All you need is a Cisco Smart Account. When the Cisco licenses expire, you can choose to renew them yourself or contact us.
As an authorized distributor of Cisco in China, we directly purchase hardware and software from Cisco China in the name of projects.

YOU MAY ALSO LIKE

Get a free consultation

Innovatively safeguards your investments for the future

Whatsapp Mail Mail WeChat
WeChat
loading