TN55TSC Is 100G tributary service processing board
Huawei OSN 8800 OTN Tributary Board TN55TSC Overview
TSC: 100G tributary service processing board
The available functional version of the TSC board are TN54 and TN55.
As a type of tributary board, the TSC board converts between one channel of 100GE/OTU4 optical signals and one channel of ODU4/ODUflex electrical signals through cross-connection.
The TSC board is mainly used to achieve cross-connection at the electrical layer.
The TSC board is mainly used to achieve cross-connection at the electrical layer.
The TSC consists of the client-side optical module, signal processing module, control and communication module, and power supply module.
There are indicators and interfaces on the front panel of the TSC board.
One slot houses one TSC board.
Specifications
Function and Feature |
Description |
||
Basic function |
TSC converts signals as follows:
|
||
Client-side service type |
100GE: Ethernet service at a rate of 103.125 Gbit/s OTU4: OTN service at a rate of 111.81 Gbit/s |
||
Cross-connect capabilities |
Supports the cross-connection of one channel of ODU4 signals between the TSC and the cross-connect board. |
||
OTN function |
NOTE: Only TN55TSC boards support PM overhead processing at the ODUflex layer. |
||
ESC function |
Supported when the client side service type is OTU4. |
||
PRBS function |
Supports the PRBS function on the client side, only when the client side service type is OTU4. |
||
LPT function |
Not supported |
||
FEC coding |
Supports forward error correction (FEC) on the client side that complies with ITU-T G.709, only when the service type is OTU4. |
||
Alarm and performance event monitoring |
Supports the remote monitoring (RMON) of Ethernet services. |
||
ALS function |
Supports the ALS function on the client side when client services are non-OTN services. |
||
Test frame |
Supported only when the client-side service type is 100GE. |
||
Latency measurement |
NOTE: This function is not supported when the client-side service type is OTU4. |
||
IEEE 1588v2 |
TN54TSC: not supported. TN55TSC: supports the TC, TC+OC, BC, and OC modes when the client-side service type is 100GE and the Port Mapping is MAC Transparent Mapping. |
||
Physical clock |
Bit Transparent Mapping ODU4 |
Mac Transparent Mapping ODU4 |
|
Supports synchronous Ethernet transparent transmission. |
Supports synchronous Ethernet processing. NOTE: The TN54TSC board does not support the synchronous ethernet processing function. |
||
Electrical-layer ASON |
Supported |
||
Ethernet service mapping mode |
TN54TSC Bit Transparent Mapping ODU4 (100G) TN55TSC Bit Transparent Mapping ODU4 (100G) MAC Transparent Mapping ODU4 (100G) |
||
Port MTU |
|
||
Protection scheme |
NOTE: Supports the tributary SNCP protection, only when the client side service type is OTU4. Client-side 1+1 protection is not supported when 100GBASE-SR10-100 m-CFP optical modules are used. |
||
Loopback |
Client side |
Inloop |
Supported |
Outloop |
|||
ODUk Inloop |
Supported NOTE: The board supports ODUk inloop and ODUk outloop only when non-OTN services are received and the port working mode is non-convergence. |
||
|